6FB1131-0BM10-2AT0 BG AT18 KOM AT18S (RoHS)
From SIEMENS
***SPARE PART*** SIDOOR CONTROL UNIT AT18S | ||
General information | ||
Product version | AT18S station platform edge door type Basic | |
Manufacturer's article no. of the usable motor | 6FB1103-0AT10-4MB0, 6FB1103-0AT11-4MB0 | |
Manufacturer's article no. of the usable power supply unit | ||
Supply voltage | ||
Design of the power supply | Via SIDOOR TRANSFORMER | |
permissible range, upper limit (DC) | 36 V | |
Input current | ||
Current consumption, max. | 10 A | |
I²t, min. | 30 A²·s | |
Encoder supply | ||
Output voltage (DC) | 24 V | |
short-circuit proof | Yes | |
Remark | Ensure correct polarity! CAUTION: Do not supply with external voltage! | |
Output current | ||
For output (24 V DC), max. | 400 mA | |
Power | ||
Active power input | 80 W | |
Active power input, max. | 230 W | |
Active power input (standby mode) | 5 W | |
Digital inputs | ||
Control inputs isolated | Yes | |
Control inputs p-switching | Yes | |
Input voltage | ||
per DC input, min. | 10 V; Observe polarity ! | |
per DC input, max. | 28 V; Observe polarity ! | |
Input current | ||
per DC input, min. | 9 mA | |
per DC input, max. | 27 mA | |
Digital outputs | ||
Relay outputs | ||
Switching capacity of contacts | ||
— at 50 V DC, min. | 0.01 A; 50 V DC switching voltage not released for NFPA-relevant countries | |
— at 50 V DC, max. | 1 A; 50 V DC switching voltage not released for NFPA-relevant countries | |
Mechanical data | ||
Opening width of door, min. | 0.3 m | |
Opening width of door, max. | 4 m | |
Weight of door, max. | 180 kg | |
Operating cycle frequency of door, max. | 180 1/h | |
Interfaces | ||
Interfaces/bus type | without | |
Degree and class of protection | ||
IP degree of protection | IP20 | |
Standards, approvals, certificates | ||
CE mark | Yes | |
UL approval | No | |
TÜV prototype tested | Yes | |
China RoHS compliance | Yes | |
Standard for EMC | EN 12015 / EN 12016 | |
Ambient conditions | ||
Ambient temperature class according to EN 50155 | T3 | |
Ambient temperature during operation | ||
min. | -20 °C | |
max. | 50 °C | |
Remark | with reduced power: -25 ... 70 °C | |
Ambient temperature during storage/transportation | ||
Storage, min. | -40 °C | |
Storage, max. | 50 °C | |
Relative humidity | ||
No condensation, min. | 10 % | |
No condensation, max. | 93 % | |
Dimensions | ||
Width | 320 mm | |
Height | 60 mm | |
Depth | 80 mm | |
last modified: | 03/13/2019 |